The Value of Diffusion Weighted MRI in the Detection and Localization of Prostate Cancer among a Sample of Iraqi Patients

Authors

  • Hiba M.Abdul Wahid College of Medicine, University of Baghdad, Baghdad, Iraq http://orcid.org/0000-0001-9517-3737
  • Ammar M. Al-Mosawe Collage of Medicine, Al-Nahrain University, Baghdad, Iraq https://orcid.org/0000-0002-3808-812X
  • Tara F. Kareem Oncology Teaching Hospital, Medical City, Baghdad, Iraq
  • Anas K. Awn National Cancer Research Center, University of Baghdad, Baghdad, Iraq
  • Qusay T. Nayyef Oncology Teaching Hospital, Medical City, Baghdad, Iraq

DOI:

https://doi.org/10.47723/kcmj.v16i2.268

Keywords:

Magnetic resonance imaging, prostate cancer, Diffusion weighted imaging, Apparent diffusion coefficient

Abstract

Background: Prostatic adenocarcinoma is the most widely recognized malignancy in men and the second cause of cancer-related mortality encountered in male patients after lung cancer.

Aim of the study:  To assess the diagnostic value of diffusion weighted imaging (DWI) and its quantitative measurement, apparent diffusion coefficient (ADC), in the identification and localization of prostatic cancer compared with T2 weighted image sequence (T2WI).

Type of the study: a prospective analytic study

Patients and methods: forty-one male patients with suspected prostatic cancer were examined by pelvic MRI at the MRI department of the Oncology Teaching Hospital/Medical City in Baghdad from September 2017 to September 2018. Thin sections axial T2 and DWI sequences were performed for each patient. Two patients were excluded from the study due to poor image quality (motion artefact). Regions with hypointense signal on T2WI and/or restricted lesion in DWI were determined. The ADC values were measured and the results were registered and sent for biopsy correlation. The sensitivity, specifity, accuracy and other parameters were calculated for T2WI and DWI.

Results: The sensitivity and specifity of T2WI in the detection of prostate cancer was about 76.6% and 77% respectively. These improved to 96% and 88.8% by performing the DWI and measuring the ADC value. The mean ADC value was greatly lower in prostatic cancer (about 650x 10-6 mm2 /s) than in normal prostate parenchyma (about 1250 x10-6 mm2 /s) with significant difference between them (p value about 0.04)

Conclusion: In practice, using diffusion weighted MRI sequence and its ADC quantitative measurement greatly increases tumor detection in patients suspicious to have prostatic cancer and should be routinely used when doing pelvic MRI for patients with high clinical suspicion.

Additional Files

Published

2020-12-30

How to Cite

1.
Wahid HM, Al-Mosawe AM, Kareem TF, Awn AK, Nayyef QT. The Value of Diffusion Weighted MRI in the Detection and Localization of Prostate Cancer among a Sample of Iraqi Patients. Al-Kindy Col. Med. J [Internet]. 2020 Dec. 30 [cited 2024 Nov. 21];16(2):45-50. Available from: https://jkmc.uobaghdad.edu.iq/index.php/MEDICAL/article/view/268

Similar Articles

11-20 of 86

You may also start an advanced similarity search for this article.